NEW PRODUCT
PD2100 Series
Marine Converter/Chargers
The
Intelligent Battery Charging System
Available With Output Ratings From 20 to 80 Amps.
Field Programmable To Properly Charge Lead-Acid, Gel-Cell, or AGM
Batteries.
Micro-Processor Controlled Four-Stage Charging System Provides Rapid
Recharge And Long Battery Life.
Patent #'s: 6,184,649 *
5,600,550 * 5,687,066 * 5,982,643 * One or more Patents pending
|
The
Inteli-Power Four-Stage Charging System
Our patented system is designed to provide the optimum charging
voltage at all times during the recharge cycle. Battery voltage
is constantly monitored by the microprocessor, which then
automatically selects one of four operating modes as follows: |
|
|
-
Storage Mode - Activated automatically when the
12 Volt systems are turned off and the battery has
been fully charged for a period of 30 hours. The
digital display will show the word STORAGE when the
unit is in this mode.
|
-
Normal Mode - Automatically selected once the
battery reaches the 90% charged level. This lower
voltage safely completes the charge and the unit will
remain in this Normal Mode as long as the 12 Volt
systems are being operated. The digital display will
show the word NORMAL when the unit is in this mode.
|
-
Exclusive Equalize Mode - Prevents battery
stratification and power robbing sulfation. When the
charger is in the Storage Mode, the microprocessor
automatically equalizes the battery by increasing the
voltage from 13.2 Volts to 14.4 Volts for 15 minutes
every 21 hours. This higher voltage remixes the
electrolyte mixture of water and sulfuric acid.
Battery manufacturers recommend that Lead-Acid
batteries be equalized every 30 days or 10 discharge
cycles.
|
What is battery stratification? - The Electrolyte
in Lead-Acid batteries is water and sulfuric acid, and
if a battery is not fully charged immediately after
discharge, the sulfuric acid begins to form a layer of
heavy concentration at the lower portion of the battery.
Our exclusive Equalize Mode prevents stratification and
sulfation.
Note: Gel-Cell and AGM batteries do not require an
Equalize Mode.

|
Lead-Acid Batteries
BOOST Voltage = 14.4 Volts
NORMAL Voltage = 13.9 Volts
STORAGE Voltage = 13.3 Volts
|
GEL-CELL Batteries
BOOST Voltage = 13.9 Volts
NORMAL Voltage = 13.3 Volts
STORAGE Voltage = 12.8 Volts
|
AGM Batteries
BOOST Voltage = 13.9 Volts
NORMAL Voltage = 13.3 Volts
STORAGE Voltage = 12.8 Volts
|
|
PD2100 Series MARINE BATTERY CHARGER SAFETY AND RELIABILITY
FEATURES:
 |
Four-Stage Charging System-
patented Microprocessor constantly monitors battery voltage
and automatically selects one of the four charging modes; BOOST,
NORMAL, STORAGE or EQUALIZE. |
 |
3 Diode Isolated Outputs-
allows the converter/charger to charge three separate banks of
batteries. Each output is capable of handling the full rated
current of the charger. |
 |
Patented Reverse Battery
Protection- prevents converter/charger from being damaged
if the batteries are accidentally connected to the charger in
reverse. |
 |
Over Voltage Protection-
prevents high voltage spikes from damaging the
converter/charger. |
 |
Electronic Current Limiting-
limits the output current to the maximum rating of the charger
to prevent overheating and damage caused by shorts or
excessive loads. |
 |
Intelligent Cooling Fan-
only runs as fast as required to maintain a more constant
operating temperature inside the converter/charger. This
feature reduces thermal stress caused by fans that cycle on
and off. |
 |
Regulated Output Voltage-
prevents AC Line voltage variations from being transmitted to
the batteries and 12 volt circuits. |
 |
Automatic Over-Temperature
Shutdown- prevents converter/charger damage in the event
the fan is unable to cool the charger due to inadequate
compartment ventilation. |
 |
Series or Parallel
Connection- Inteli-Power Converter/Chargers can be
connected in series to provide a combination 12/24 Volt
system, or in parallel to provide more current. |
SPECIAL FEATURES:
 |
Digital Meter
- Displays Current, Voltage, Operation Mode, Blown Fuse Indication, and
Battery Type. |
 |
Programmable in the Field-
to provide optimum charging profiles for lead-acid, gel-cell,
or AGM batteries. |
 |
Built-In Self Test |
|
|
 |

|
Inteli-Power Converter/Chargers can
be connected in series to provide a combination 12/24 Volt system,
or in parallel to provide more current (as shown below). |
 |
 |
PD2100 Series Specifications Table
| |
PD2120 |
PD2130 |
PD2140 |
PD2150 |
PD2160 |
PD2180 |
|
Number of Battery Banks |
3 |
3 |
3 |
3 |
3 |
3 |
|
Maximum Continuous DC Output Current - Available on each
output |
20-AMPS |
30-AMPS |
40-AMPS |
50-AMPS |
60-AMPS |
80-AMPS |
|
Maximum Continuous Input Power |
350 WATTS |
550 WATTS |
650 WATTS |
900 WATTS |
1,000 WATTS |
1,300 WATTS |
|
DC Output Voltage (Normal) |
13.9 VDC |
13.9 VDC |
13.9 VDC |
13.9 VDC |
13.9 VDC |
13.9 VDC |
|
DC Output Voltage (Boost) |
14.4 VDC |
14.4 VDC |
14.4 VDC |
14.4 VDC |
14.4 VDC |
14.4 VDC |
|
DC Output Voltage (Storage) |
13.3 VDC |
13.3 VDC |
13.3 VDC |
13.3 VDC |
13.3 VDC |
13.3 VDC |
|
Full Load Output Voltage (Normal) |
>
12.6 VDC |
>
12.6 VDC |
>
12.6 VDC |
>
12.6 VDC |
>
12.6 VDC |
>
12.6 VDC |
|
Input Voltage |
105 - 130 VAC |
105 - 130 VAC |
105 - 130 VAC |
105 - 130 VAC |
105 - 130 VAC |
105 - 130 VAC |
|
Input Voltage Frequency |
50-60 HZ |
50-60 HZ |
50-60 HZ |
50-60 HZ |
50-60 HZ |
50-60 HZ |
|
Peak Inrush Current |
32-AMPS |
32-AMPS |
32-AMPS |
47-AMPS |
47-AMPS |
80-AMPS |
|
Efficiency (Typical) |
>
80% |
>
80% |
>
80% |
>
80% |
>
80% |
>
80% |
|
Reverse Battery Protection |
YES |
YES |
YES |
YES |
YES |
YES |
|
Electronic Current Limiting |
YES |
YES |
YES |
YES |
YES |
YES |
|
Over Voltage Protection |
YES |
YES |
YES |
YES |
YES |
YES |
|
Electronic Fan Control * |
ON/OFF |
ON/OFF |
ON/OFF |
ON/OFF |
ON/OFF |
ON/OFF |
|
Back Up Thermal Protection |
YES |
YES |
YES |
YES |
YES |
YES |
|
Ignition Protected |
YES |
YES |
YES |
YES |
YES |
YES |
|
Storage Temperature |
-20C to +80C |
-20C to +80C |
-20C to +80C |
-20C to +80C |
-20C to +80C |
-20C to +80C |
|
Operating Temperature |
-10C to +50C |
-10C to +50C |
-10C to +50C |
-10C to +50C |
-10C to +50C |
-10C to +50C |
|
Hipot Voltage Test |
<--------------
1240 V @ INPUT TERMINALS ------------> |
|
Onboard CHARGE WIZARD With Automatic 4-Mode Charging
|
YES |
YES |
YES |
YES |
YES |
YES |
|
Weight |
5.7 LBS. |
5.8 LBS. |
5.9 LBS. |
6.3 LBS. |
6.4 LBS. |
9.2 LBS. |
|
Dimensions |
10.9"L X 7.8"W X 4.2"H |
10.9"L X 7.8"W X 4.2"H |
10.9"L X 7.8"W X 4.2"H |
10.9"L X 7.8"W X 4.2"H |
10.9"L X 7.8"W X 4.2"H |
15.2"L X 7.8"W X 4.2"H |
|
Marine UL & c UL Listed |
YES |
YES |
YES |
YES |
YES |
YES |
*
Fan controlled by temperature sensor normally operates
only during high load or high ambient temperature conditions.
All
output voltages are +/- 0.3 VDC and specified for lead
acid type batteries. All voltages are 0.4 VDC lower
for gel type batteries.
View The Inteli-Power PD2100
Operation
Manual
View The Inteli-Power
PD2100 Series
Owner's Manual
Return to Previous Page
|